GW type non-clogging pipeline sewage pump
GW-type non-clogging sewage pump is suitable for conveyor belt particles in industries such as chemical, petroleum, pharmaceutical, mining, paper industry, cement plant, steel plant, power plant, coal processing industry, and urban sewage treatment plant drainage system, municipal engineering, construction site, etc. The waste water and dirt are also used for pumping clean water and corrosive media.
product description:
The GW type non-clogging submersible sewage pump has the characteristics of significant energy saving effect, anti-winding, non-clogging, automatic installation and automatic control. It has a unique effect in discharging solid particles and long-fiber waste.
This series of sewage pumps is a new generation of pump products successfully developed based on the characteristics of water pumps. Adopting a unique impeller structure and a new type of mechanical seal, it can effectively transport solids and long fibers. Compared with the traditional impeller, the impeller of the pump adopts a single-channel or double-channel form, which is similar to an elbow with the same cross-section and has very good flowability. Equipped with a reasonable volute, the pump is efficient The high and impeller have undergone dynamic and static balance tests, so that the pump has no vibration during operation.
 
Features:
1. The pump and the motor are directly connected coaxially, which is a mechatronics product with compact structure and stable performance.
2. The design of the anti-clogging hydraulic components of the large flow channel greatly improves the dirt passing capacity, and can effectively pass 5 times the diameter of the pump caliber and solid particles with a diameter of about 50% of the pump caliber.
3. Reasonable design, reasonable supporting motor, high efficiency, low noise and significant energy saving effect.
4. The mechanical seal is made of hard wear-resistant tungsten carbide, which has the characteristics of durability and wear resistance, which can make the pump safe and continuous operation for more than 8000 hours.
5. The pump is a vertical structure, the center line of the inlet and outlet are on the same horizontal line, and the specifications of the inlet and outlet flanges are the same, so installation and disassembly are very convenient.
6. The area is small, no need to build a machine room, which can save a lot of infrastructure costs; add a protective cover to the fan end of the motor, and the whole machine can be placed outdoors.
 
Installation and use:
1. **First check whether the external fasteners are loose during transportation.
2. Check whether the power supply voltage meets the requirements of the motor nameplate.
3. Turn on the power and make a trial run to see if the impeller turns in the direction indicated on the pump. If the direction is reversed, just reverse any two-phase wires in the cable. The trial run should not take too long to avoid burning the seal. .
4. Install the pump and start it up and running. The pump foot screws can be installed.
 
Inspection and maintenance:
1. Before using the pump, check the insulation resistance of the motor winding to the casing. If it is less than 0.5 megohm, the stator must be dried just after the insulation resistance rises.
2. If the gap between the impeller and the oil seal at the inlet of the pump body exceeds 2mm, the wear-resistant oil seal should be replaced.
3. When the pump seal leaks, the seal should be replaced in time. When replacing the static seal, install the static seal flat, and then install the dynamic seal on the shaft.
4. When replacing the impeller, pull it out with a tensioner, and don't hit it with a hammer, so as not to damage the axis.
 
Common causes of failure:
1. No water is discharged, the pumped liquid is heavy and the particle size is too high; the liquid flow channel is blocked; the impeller turns wrong; the rod is drawn into the impeller and is jammed; the outlet height of the pipe exceeds the rated lift height.
2. Insufficient flow and low lift. The voltage is too low, the impeller turns wrongly or the wear-resistant seal is worn; the liquid has a heavy particle size.
3. The insulation resistance is low, the surrounding environment is humid, and the mechanical seal is seriously leaking.
 
 Model meaning:


 

GW管道无堵塞排污泵型号 口径 流量 扬程 转速 电机功率 效率
mm m3/h M r/min kw %
GW25-8-22-1.1 25 8 22 2900 1.1 45
GW32-12-15-1.1 32 12 15 2900 1.1 49
GW40-15-15-1.5 40 15 15 2900 1.5 54
GW40-15-30-2.2 40 15 30 2900 2.2 54
GW50-20-7-0.75 50 20 7 2900 0.75 51
GW50-10-10-0.75 50 10 10 2900 0.75 52
GW50-20-15-1.5 50 20 15 290 1.5 53
GW50-15-25-2.2 50 15 25 2900 2.2 54
GW50-18-30-3 50 18 30 2900 3 55
GW50-40-15-4 50 40 15 2900 4 55
GW50-25-32-5.5 50 25 32 2900 5.5 55
GW50-20-40-7.5 50 50 20 2900 7.5 58
GW65-25-15-2.2 65 25 15 2900 2.2 50
GW65-37-13-3 65 37 13 2900 3 57
GW65-25-30-4 65 25 30 2900 4 61
GW65-30-40-7.5 65 30 40 2900 7.5 56
GW65-35-50-11 65 35 50 2900 11 45
GW65-35-60-15 65 35 60 2900 15 65
GW80-60-13-5.5 80 60 13 2900 5.5 67
GW80-40-7-2.2 80 40 7 1450 2.2 59
GW80-43-13-3 80 43 13 2900 3 70
GW80-40-15-4 80 40 15 2900 4 61
GW80-65-25-7.5 80 65 25 2900 7.5 63
GW100-80-10-4 100 100 10 1450 4 65
GW100-110-10-5.5 100 110 10 1450 5.5 65
GW100-100-15-7.5 100 100 15 1450 7.5 68
GW100-80-20-7.5 100 80 20 1450 7.5 65
GW100-100-25-11 100 100 25 1450 11 70
GW100-100-30-15 100 100 30 1450 15 65
GW100-100-35-18.5 100 100 35 1450 18.5 68
GW125-130-15-11 125 130 15 1450 11 72
GW125-130-20-15 125 130 20 1450 15 75
GW150-145-9-7.5 150 145 9 1450 7.5 76
GW150-180-15-15 150 180 15 1450 15 69
GW150-180-20-18.5 150 180 20 1450 18.5 72
GW150-180-25-22 150 180 25 1450 22 78
GW150-130-30-22 150 130 30 1450 22 78
GW150-180-30-30 150 180 30 1450 30 78
GW150-200-30-37 150 200 30 1450 37 73
GW200-300-7-11 200 300 7 980 11 66
GW200-250-11-15 200 250 11 1450 15 64
GW200-250-15-18.5 200 250 15 1450 18.5 73
GW200-400-10-22 200 400 10 1450 22 75
GW200-400-13-30 200 400 13 1450 30 76
GW200-300-15-22 200 300 15 1450 22 76
GW200-250-22-30 200 250 22 1450 30 71
GW200-350-25-37 200 350 25 1450 37 71
GW200-400-30-45 200 400 30 1450 45 74
GW250-600-9-30 250 600 9 980 30 78
GW250-600-12-37 250 600 12 1450 37 76
GW250-600-15-45 250 600 15 1450 45 73
GW250-600-20-55 250 600 20 1450 55 73
GW250-600-25-75 250 600 25 1450 75 71
GW300-800-12-45 300 800 12 980 45 74
GW300-480-15-45 300 480 15 1450 45 66
GW300-800-15-55 300 800 15 1450 55 73
GW300-600-20-55 300 600 20 1450 55 73
GW300-800-20-75 300 800 20 1450 75 75
GW300-950-20-90 300 950 20 1450 90 76
GW300-1000-25-110 300 1000 25 1450 110 76
GW300-1100-10-55 300 1100 10 1450 55 73
GW350-1500-15-90 350 1500 15 740 90 87
GW350-1200-18-90 350 1200 18 980 90 85
GW350-1100-28-132 350 1100 28 980 132 84
GW350-1000-36-160 350 1000 36 980 160 84
GW400-1760-7.5-55 400 1760 7.5 980 55 83
GW400-1500-10-75 400 1500 10 980 75 86
GW400-2000-13-110 400 2000 13 980 110 84
GW400-2000-15-132 400 2000 15 980 132 83
GW400-1700-22-160 400 1700 22 980 160 83
GW400-1500-26-160 400 1500 26 980 160 84
GW400-1700-30-200 400 1700 30 980 200 86
GW400-1800-32-250 400 1800 32 980 250 82
GW500-2500-10-110 500 2500 10 740 110 85
GW500-2600-15-160 500 2600 15 740 160 84
GW500-2400-22-220 500 2400 22 740 220 85
GW500-2650-24-250 500 2650 24 740 250 85
 

 